Skip to main content
Featured Products

Ex-proof Control Panel

Ex db IIB+H2 T5 certified control panels for generators, pumps and motor starters in Zone 1/Zone 2 areas.

  • Certified for Zone 1 Ex db IIB+H2 T5
  • Generator, pump & motor starter configurations
  • Customize panel builds available
  • Factory acceptance testing included
EU-TYPE EXAMINATION CERTIFICATE:AR20ATEX006

Request a Quote

Need help first? Contact Sales@cemengrg.com

Overview

Explosion-proof control panels covering generator control, pump control, motor starters and fully customised configurations for hazardous-area installations.

Specifications

Hazardous Area ClassificationATEX Zone 1 2G Ex d b IIB+H2 T5/T6 Gc
ApplicationSwitch Gear/Generator/Compressor/Pump/ Motor Starter
Communication / Remote InterfacingEthernet/RS-485 / Hardwire
Enclosure MaterialsSS316/SS316L

Generator Control Panel

Ex d/Ex e rated control and protection panel for generator sets, covering local emergency stop, shutdown override, starter mode selection, engine start/stop and generator circuit breaker control from a single flameproof enclosure.

Enclosure Rating Ex db IIB T5 (typical — confirm per project)
Ingress Protection IP65
Functions Local emergency stop, shutdown override, starter mode select, engine start/stop, GCB on/off

Certifications: EU-TYPE EXAMINATION CERTIFICATE, AR20ATEX006

Ex d generator control panel

Generator Control Panel

Ex d generator control panel Ex d genset controller — start/stop, shutdown override, starter mode selection

Ex d/Ex e rated control and protection panel for generator sets, covering local emergency stop, shutdown override, starter mode selection, engine start/stop and generator circuit breaker control from a single flameproof enclosure.

Enclosure RatingEx d IIB T3 (typical — confirm per project)
Ingress ProtectionIP65/IP66 (typical)
FunctionsLocal emergency stop, shutdown override, starter mode select, engine start/stop, GCB on/off

Certifications: ATEX Directive 2014/34/EU; IECEx Certificate of Conformity.

More in This Range
Zone 2 DEG offshore installation 2 30 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit pasted-image-1784815536106-1 Zone 2 DEG and GEG 30 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 30 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 30 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 45 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 45 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 45 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 60 kVA Zone 2 diesel generator — ATEX Zone 2 certified open-frame skid unit 60 kVA Zone 2 diesel generator — ATEX Zone 2 certified open-frame skid unit 60 kVA Zone 2 diesel generator — ATEX Zone 2 certified open-frame skid unit 60 kVA Zone 2 diesel generator — ATEX Zone 2 certified open-frame skid unit 45 kVA Zone 2 diesel generator — ATEX Zone 2 3G IIB T3, angled view 30 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 30 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 30 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 30 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 45 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 45 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 45 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 45 kVA Zone 2 diesel generator — ATEX Zone 2 certified skid unit 60 kVA Zone 2 diesel generator — ATEX Zone 2 certified open-frame skid unit 60 kVA Zone 2 diesel generator — ATEX Zone 2 certified open-frame skid unit 60 kVA Zone 2 diesel generator — ATEX Zone 2 certified open-frame skid unit 60 kVA Zone 2 diesel generator — ATEX Zone 2 certified open-frame skid unit Featured Products

Zone 2 Diesel Engine Generator \ Zone II Genset

ATEX/IECEx certified Zone 2 diesel generator for oil, gas and offshore hazardous-area power supply.

20KVA Zone 2 Diesel Engine generator Zone 2 genset Featured Products

20kVA Zone 2 Diesel Engine Generator /Zone II Genset

20 kVA ATEX Zone 2 diesel generator featuring a ComAp MRS16 microprocessor controller with PLC logic, automatic protection, event history, fault diagnostics, and remote monitoring and control.

Ask CEM Engineering AI
Hi! I'm the CEM Engineering assistant. Ask me about ATEX/IECEx Zone 2 equipment, certifications or getting a quote.